Immediate implant placement in conjunction with a DFDBA graft and resorbable membrane: A 1-10 year retrospective clinical study


Smile Care Clinic (P) Ltd., Bandra (W), Mumbai - 400 050, India

Correspondence Address:
Ratnadeep C Patil
Smile Care Clinic Pvt. Ltd., 13, Geetanjali, 234 S.V. Road, S. V. Road, Bandra (W), Mumbai - 400 050
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.21637

Rights and Permissions
  Abstract 

Context: The use of immediate post-extraction implants presents several advantages in terms of reduction of surgical steps and time required to conclude the therapy. Particularly important is the possibility to minimize the bone loss that otherwise would occur in the physiologic healing of the alveolus. Aim: The purpose of this paper is to evaluate immediate implants placed with DFDBA grafts and resorbable membrane over a 10-year period based on parameters of stability, success rate, esthetics and functional integrity to evaluate predictability of this surgical technique. Settings and Design: Unicenteric, randomized clinical study. Methods and Materials: From Jan 1995 to Jan 2005, 81 immediate extraction implants were placed for 68 patients. 75 Stepped screw Frialit2, Friadent, Gmbh, Mannheim, Germany) implants and 7 Straight, Swiss-Plus self-tapping threaded implants (Zimmer, Centrepulse) were placed. Observation period ranged from minimum 6 months to maximum 10 years. Statistical analysis used: Descriptive statistics, Chi-square test and One-way Anova test were used for assessing survival rates by comparing various variables like bone quality, bone quantity, implant sizes, implant site and problems encountered during and after surgery. Results: The 10-year survival rate was 98.76%. Majority of the implants placed showed diameter and length equal to or more than root size. Conclusions: Immediate implant placement has helped solve issues with regard to bone quantity, quality and esthetics as also treatment time, as opposed to delayed implant placement. Needless to mention is the instant gratification it provides the patient.

Keywords: Aesthetics, dental implants, immediate implants, osseointegration, DFDBA


How to cite this article:
Patil RC, Kanchan S, Ramanathan K. Immediate implant placement in conjunction with a DFDBA graft and resorbable membrane: A 1-10 year retrospective clinical study. J Indian Prosthodont Soc 2005;5:203-7

How to cite this URL:
Patil RC, Kanchan S, Ramanathan K. Immediate implant placement in conjunction with a DFDBA graft and resorbable membrane: A 1-10 year retrospective clinical study. J Indian Prosthodont Soc [serial online] 2005 [cited 2019 Jul 20];5:203-7. Available from: http://www.j-ips.org/text.asp?2005/5/4/203/21637


  Introduction Top


Implant Dentistry has come a long way from skepticism to being accepted as the best modality to treat complete or partial edentulism. In the last two decades a great deal of activity in the field has occurred with the development of better materials and newer techniques that have resulted in improved clinical performance of implants. The advent of immediate extraction implants and immediate loading has however proved to be an interesting point in implant dentistry.

Following extraction, a healing period of four to six months has been considered mandatory for implant placement. This time-frame was established using clinical observation of machined-surface dental implants of the first generation, caution being taken to avoid fibrous encapsulation and overloading of peri-implant necrotic bone with subsequent implant failure.[1] This procedure however leads to some volume of crestal bone resorption, loss of interpapillary volume and eventual compromise in esthetics - 'black triangle effect'. Also due to labial bony plate being resorbed at a faster rate than the remaining bone, a gradual diminishing of the emerging profile is noticed.[2] New implant surfaces have been developed since, and research shows evidence of enhanced osseointegration capabilities for an increased bone-to-implant contact.[3]

Controlled clinical studies have demonstrated an average of 4.4 mm of horizontal and 1.2 mm of vertical bone resorption 6 months after tooth extraction.[4]

Experimental animal researches and clinical studies demonstrated that the immediate implant placement reduces alveolar resorption.[5],[6],[7]

In short, implant size and angulation are equal to or more than the tooth. Literature reviews have proved beyond doubt that wider and/ or longer implants are desirable for better stress distribution.[8]

In cases where implants are immediately placed into extraction sites, there is often a void adjacent to the head of the implant due to discrepancies in size and shape between implant and extraction orifice. A number of researchers have reported on barrier membranes or grafting materials used for exclusion of epithelium so that bone could fill up the void.[9]

The application of the proposed protocol is considered in clinical situations such as root fractures, endodontic - periodontal complications and periodontal failures. Documented success rates exceeding 95% after three to ten years of function suggest favorable long-term prognosis for immediate single tooth replacement with implant supported restoration.[10],[11]


  Materials and Methods Top


This was a unicentric, retrospective, randomized clinical study with the purpose of evaluating the efficacy of a surgical protocol using immediate implants for a single tooth implant replacement.

From Jan 1995 to Jan 2005, 81 immediate extraction implants were placed for 68 patients. 48 male and 20 female patients entered the RCT clinical trial. Observation period ranged from six months to ten years post loading. Data collection for patients included the following parameters - Patient details, medical history, bone quality and quantity, non loading period, post loading recall (absence of pain, discomfort, peri-implant infection, peri-implant radiolucency, mobility) esthetic results were evaluated based on Keratinised Mucosa Width (KMW) and emergence profile or the Esthetic Line (EL) of the implant crown with respect to the soft tissue and emergence profile of neighboring teeth and patient satisfaction regarding esthetics and comfort with treatment outcome (based on German school grading system wherein 1 - very good, 2 - good, 3 - satisfactory, 4- sufficient, 5 - unsatisfactory, 6 - insufficient) Patient selection was restricted to patients who showed a need and motivation for the implant procedures. Chief criteria were absence of severe systemic problems and acute local infection, no alcohol or drug dependency. Additional local criteria were good oral hygiene, stable occlusion of the existing teeth and adequate vertical dimension.

75 Stepped screw Frialit 2 (Friadent, Gmbh, Mannheim, Germany) implants and 7 Straight Swiss-Plus self tapping threaded (Zimmer Centrepulse) implants were placed.

Clinical case

[Figure - 1][Figure - 2] illustrate an endodontically treated upper left 1st molar with root resorption and mobility in a female patient aged 26 years. Following atraumatic extraction to preserve labial and lingual bony plates, the socket was cleaned and checked for presence of granulation tissue. [Figure - 3] The length of the extracted root was determined with the help of a scale and the available bone depth was measured. The osteotomy was deepened with at least 30% more depth and enlarged till maximum contact of bone is attained wherever possible. A stepped screw root form Frialit-2 (Friadent, Gmbh, Mannheim, Germany) implant size 3.8 mm x 15 mm was placed into the immediate extraction socket. The open spaces especially at the neck of the implant fixture were filled up with DFDBA and sutures were placed to attain complete closure of the wound. [Figure - 4] A fiber splint (Polydentia SA, Switzerland) was used to act as a palatal splint for the provisional fabricated from the patient's extracted tooth. [Figure - 6], [Figure - 7] Following a healing period of 4-6 months the second stage surgery was performed and a healing abutment kept in place for a period of 2 weeks. [Figure - 8] Final impressions following soft tissue healing were taken and final metal ceramic prosthesis was cemented [Figure - 9].

Statistics

Descriptive statistics, Chi-square test and One-way Anova test were used for assessing survival rates by comparing various variables like bone quality, bone quantity, implant sizes, implant site and problems encountered during and after surgery.


  Results Top


Of the 81 implants 44 were placed in the maxilla and 37 in the mandible. Age of the patients ranged between 19-69 years. One out of the 81 implants showed delayed failure five months post loading due to periimplantitis. The 10-year survival rate was 98.76%. Of the 68 patients one had history for smoking and 12 for hypertension. Bone quality (BQL) was sufficient in 41 cases, good in 13 cases and poor in 27 cases. Bone quantity (BQT) was sufficient in 77 cases, height was less than ideal in one case, width was less than ideal in one case and labial plate was fractured in 2 cases. 13 mm x 4.5 and 5.5 mm were the most preferred implant sizes (28%). Only three diameter values 3.8 mm, 4.5 mm and 5.5 mm cover 83% of cases. There was no case with diameter less than 3.3 mm. In case of length 13 mm was most frequently used (48% cases). Lengths 10 mm and 15 mm were used in equal number of cases and together covered about 43% cases. There was only one case with implant length below 10 mm.

65.3% cases showed KMW optimal (more than or equal to 2 mm) and 34.8% cases showed KMW < 2 mm. All prosthetic crowns showed optimal EL.

Patient satisfaction measured with German School Grading system showed that out of 68 patients 41 said treatment outcome was very good, 20 said good, 6 said satisfactory and one said unsatisfactory.


  Discussion Top


Immediate implants placed in fresh extraction sockets are a proven and predictable treatment modality. Immediate implant placement has helped solve issues with regard to bone quantity, quality and esthetics as also treatment time, as opposed to delayed implant placement.

Its advantages are evident in that flapless technique and use of implant sizes are more than/ equal to root size, allows lesser resorption and morphological ridge contour preservation. Moreover, this surgical procedure also allows a better final rehabilitation since it facilitates accurate prosthetic fabrication while maintaining the natural tooth angle and emergence profile. Needless to mention is the instant gratification it provides the patient.

Immediate extraction implant however requires careful case selection and careful extraction of the tooth. Achieving good primary stability is the key factor in success of immediate implants since stability is often achieved with the bone to implant contact in the apical drilled portion of the osteotomy. In the event of buccal plate fracture during extraction, grafts and GBR techniques maybe used to improve prognosis only if sufficient primary stability of the implant maybe achieved.

Studies with patient satisfaction clearly indicate that a substantial number of patients were highly satisfied with immediate implant-supported prostheses over fixed bridges and soft tissue supported prostheses. As research avenues span across newer surgical techniques and materials our constant endeavor as clinicians is to provide our patients with predictable, functionally and esthetically sound treatment.


  Acknowledgement Top


Dr. Sharayu Paranjpe, Reader, Dept. of Statistics, Univ. of Pune[Figure - 10].

 
  References Top

1.
Lazzara RJ, Porter SS, Testori T, Galante J, Zetterqvist L. A Prospective Multicenter Study Evaluating Loading of Osseotite Implants Two Month After Placement: One-Year Result. J Esthet Dent 1998;10:280-9.  Back to cited text no. 1
[PUBMED]  [FULLTEXT]  
2.
Bianchi AE, Sanfilippo F. Single-tooth replacement by immediate implant and connective tissue graft: a 1-9 year clinical evaluation. Clin Oral Implant Res 2004;15:269-77.  Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.
Lazzara R. Immediate implant placement into extraction sites. Int J Periodont Restorat Dentist 1989 5:333-4.  Back to cited text no. 3
    
4.
Strub JR, Kohal RJ, Klaus G. The Re Implant system for immediate implant placement. J Esthet Dent 1997;9:187-96.   Back to cited text no. 4
    
5.
Wheeler SL, Vogel RE, Casellini R. Tissue preservation and maintenance of optimum esthetics:a clinical report. Int J Oral Maxillofac Implant 2000;2:265-71.  Back to cited text no. 5
    
6.
Parr GR, Steflik DE, Sisk AL. Histomorphometric and histologic observations of bone healing around immediate implants in dogs. Int J Oral Maxillofac Implant 1993:5:534-40.  Back to cited text no. 6
    
7.
Barzilay I, Graser GN, Iranpour B, Proskin HM. Immediate implantation of pure titanium implants into extraction sockets of Macaca fascicularis. Part I clinical and radiographic assessment. Int J Oral Maxillofac Implant 1996:3:299-310.  Back to cited text no. 7
[PUBMED]  [FULLTEXT]  
8.
Rangert Bo, Renouard F. Risk Factors in Implant Dentistry: Simplified Clinical Analysis for Predictable Treatment.  Back to cited text no. 8
    
9.
Coatoam GW, Mariotti A. Immediate placement of anatomically shaped dental implants. J Oral Implantol 2000:26;170-6.  Back to cited text no. 9
[PUBMED]  [FULLTEXT]  
10.
Schiroli G. Immediate tooth extraction, Placement of a tapered screw-Vent Implant and Provisionalization in the Esthetic Zone: A Case Reoprt. Implant Dent 2003;12:123-9.  Back to cited text no. 10
[PUBMED]  [FULLTEXT]  
11.
Priest G. Single tooth implants and their role in preserving remaining teeth: A 10 - year Survival study. Int J Oral Maxillofac Implant 1999;14:181-8.  Back to cited text no. 11
[PUBMED]  [FULLTEXT]  


    Figures

  [Figure - 1], [Figure - 2], [Figure - 3], [Figure - 4], [Figure - 5], [Figure - 6], [Figure - 7], [Figure - 8], [Figure - 9], [Figure - 10]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and Me...
Statistics
Results
Discussion
Acknowledgement
References
Article Figures

 Article Access Statistics
    Viewed7551    
    Printed111    
    Emailed4    
    PDF Downloaded453    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]