• Users Online: 222
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 


 
 Table of Contents  
CLINICAL REPORT
Year : 2008  |  Volume : 8  |  Issue : 2  |  Page : 112-115

Use of acrylic resin base as an aid in retaining silicone orbital prosthesis


1 Department of Prosthodontics, SDM Dental College, Sattur, Dharwad, Karnataka, India
2 GDC, Bellary, India

Date of Web Publication27-Oct-2008

Correspondence Address:
Satyabodh S Guttal
Department of Prosthodontics, SDM College of Dental Sciences and Hospital, Sattur, Dharwad - 580 009, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.43615

Clinical trial registration None

Rights and Permissions
  Abstract 

Orbital defects with total loss of eyelids and eyeball cannot be satisfactorily repaired by reconstructive surgery. While prosthetic replacement is the treatment of choice owing to its acceptable and life-like appearance, retention of the orbital prosthesis is an important factor for success of the prosthesis. This paper describes a technique for retention of silicone orbital prosthesis using acrylic resin base, wherein the latter is attached to the eyeglass frame.

Keywords: Artificial eye, maxillofacial prosthesis, retention aids


How to cite this article:
Guttal SS, Patil NP, Nadiger RK, Rachana K B, Dharnendra, Basutkar N. Use of acrylic resin base as an aid in retaining silicone orbital prosthesis. J Indian Prosthodont Soc 2008;8:112-5

How to cite this URL:
Guttal SS, Patil NP, Nadiger RK, Rachana K B, Dharnendra, Basutkar N. Use of acrylic resin base as an aid in retaining silicone orbital prosthesis. J Indian Prosthodont Soc [serial online] 2008 [cited 2019 Jul 24];8:112-5. Available from: http://www.j-ips.org/text.asp?2008/8/2/112/43615


  Introduction Top


Total orbital exenteration is a radical surgical procedure which typically involves removal of the entire contents of the orbit, including periorbita. Consequently, it results in a deep orbital deformity in the patient with devastating cosmetic and functional implications that require expensive and technically challenging oculoplastic intervention, not to mention associated psychological effects. Orbital prosthesis presents an attractive and viable alternative when esthetic and functional demands are beyond the capacity of local reconstructive efforts. [1]

Prostheses for orbital defects can be made from a variety of materials such as polymethyl methacrylate, polyurethane elastomer, silicone elastomer, or urethane-backed medical grade silicone. They are usually retained by adhesives, tissue undercuts, or, in some instances, extraoral osseointegrated implants. [2],[3],[4],[5] Eyeglass frames have been the medium of choice in anchoring orbital prosthesis with a variety of base materials and accessory-retentive features such as bar-clips, snaps, and magnets. [6],[7],[8],[9],[10]

Ablative surgical procedure incurs major financial burden, and hence the patient may seek a prosthetic treatment that is economical. Therefore, selection of a reasonable maxillofacial prosthetic material and economically feasible retentive aid should be the goal of rehabilitating such patients. Since silicone has better marginal adaptation and life-like appearance, it has been used for the fabrication of orbital prostheses. [11] A limitation of silicone orbital prostheses is its lack of chemical/mechanical bonding with the eyeglass frame, making it difficult to retain the prosthesis. This paper describes a method of fabricating the silicone orbital prosthesis which is attached to the eyeglass frame using acrylic resin base. The method is employed for treating two identical cases with orbital defect.


  Case Reports Top


Case 1

A 45-year-old female was referred to the Department of Maxillofacial Prosthetics at our institution. The patient complained of facial disfigurement due to loss of the left eye, and a history of carcinoma of the left eye followed by exenteration was recorded. As a result of altered facial esthetics, the patient suffered severe emotional trauma in terms of social acceptance.

Case 2

A 58-year-old female was referred to the aforementioned department. The patient complained of missing right orbital contents following the surgery due to adenoid cystic carcinoma [Figure 1].

We learnt that both the patients were seeking an artificial orbital replacement. On examination, there was no anatomical undercut in the defect that could be utilized for retention. A custom-made ocular and orbital prosthesis was planned and the treatment procedure explained to the patient. Identical methods were employed to verify the reliability of the results in both patients.

Procedure

  1. The patient was placed in the supine position and draped for impression procedures; the patient's eyebrows and eyelashes were lubricated with petroleum jelly.
  2. Impression of the orbital defect was made using irreversible hydrocolloid reinforced with dental plaster and the cast poured in dental stone [Figure 2].
  3. The stone cast was duplicated with silicone duplicating material in a metal flask. After the duplicating material set, the master cast was separated and stone cast poured in the mould.
  4. Wax pattern for the acrylic resin base was made in a circumferential design adapting it to the perimeter of the defect.
  5. The pattern was sealed to the cast and invested. After wax elimination, heat polymerizing acrylic resin was packed. Intrinsic coloring was applied to match the skin color around the patient's defect.
  6. Curing was carried out. The resin base was retrieved, finished, and polished. The fit of the base was checked on the cast [Figure 3].
  7. Different aids were used in aligning the artificial eye, after which it was positioned in the defect. [12] Artificial eye can either be custom-made or stock eye, the former being used in this case.
  8. The wax pattern for the orbital prosthesis was prepared and the acrylic resin base embedded in it. The acrylic resin base was exposed only at the bridge of the nose for attachment to the eyeglass frame [Figure 4].
  9. Try-in of the waxed-up prosthesis was done [Figure 5]. At this stage the eyeglass frame was selected and tried on the patient, and close approximation of the eyeglass frame to the resin base was checked.
  10. The wax pattern was sealed to the cast, flasking carried out and wax eliminated [Figure 6].
  11. Primer was applied to the acrylic resin base for bonding with silicone.
  12. The silicone was packed. Intrinsic coloring was produced to match the patient's skin tone and cured at room temperature.
  13. The prosthesis was retrieved, finished, and initial trial taken. The eyeglass frame was placed in situ. If the silicone layer was found to be covered on the medial extension of the resin base, it was cut and exposed. This facilitates the attachment of the eyeglass frame to the resin base.
  14. With both the eyeglass frame and prosthesis placed in situ, the glass frame was attached to the acrylic resin base with the help of cyanoacrylate resin adhesive. The attachment was reinforced with autopolymerizing acrylic resin [Figure 7].
  15. Finally the silicone orbital prosthesis retained by the eyeglass frame was placed in situ [Figure 8]. Similarly all the steps were carried out for case 2 [Figure 9] and [Figure 10].
  16. Home care instructions were given, and follow-up evaluation was carried out, at which time the prosthesis was noted to be functioning well.



  Discussion Top


Technique used for retaining maxillofacial prostheses plays an important role in the success of treatment. Osseointegration concepts for retaining the orbital prosthesis are well documented. [13],[14],[15] Because of financial constraints, patients, in general, do not always have the liberty to opt for the implant-retained prosthesis. Modern prosthetic replacements are secured with adhesives that are readily available, easily applied, and provide satisfactory retention for a limited period of time. However, continual use of adhesives may cause allergic response or irritation. [16]

Conventionally retained orbital prostheses are practical, trouble-free, cost-efficient, and successful. [2] The most commonly used conventional method to retain orbital prostheses is the eyeglass frames and anatomic retentive undercuts. Anatomic retention can help retain an orbital prosthesis by using a flexible conformer in the defect space; the orbital prosthesis is constructed in the usual manner with an extension into the conformer engaging the circumferential groove undercut to provide mechanical retention. [16] However, there should be adequate anatomic undercut to use this technique.

The patient treated in this report had no anatomical defect; hence an eyeglass frame was the only alternative to retain the silicone orbital prosthesis. The shortcoming of using silicone elastomer to fabricate an orbital prosthesis retained by eyeglass frame is that no bonding between silicone and the frame is achieved. The use of acrylic resin base aids in attachment to the eyeglass frame, as well as bonding to the silicone.

Acrylic resin is a simple and economical base material for use in retaining the orbital prosthesis. Previously, some reports have described the fabrication of acrylic resin orbital prosthesis attached to an eyeglass frame; [17],[18] however, the advantage of the present method is the use of silicone elastomer, which has better marginal adaptation (knife edge margins can be produced) and is lightweight. In particular, silicone produces a more life-like appearance. The silicone orbital prosthesis was comfortable to wear and caused no irritation to the surrounding skin. The patient started wearing the prosthesis routinely and was satisfied with the cosmetic result. She had recommenced attending her pre-surgical social events comfortably.


  Summary Top


A simple procedure of fabricating an eyeglass frame-retained silicone orbital prosthesis has been presented. The method used acrylic resin base for attaching the eyeglass frame to the silicone prosthesis. The advantages of this method are its cost-effectiveness, tissue tolerance, esthetics, and comfort for use and wear.


  Acknowledgments Top


The authors gratefully acknowledge the support and encouragement given by their Principal, Prof. C. Bhasker Rao. The authors also thank Dr. Ashith B. Acharya for assistance in manuscript preparation.

 
  References Top

1.
Konstantinidis L, Scolozzi P, Hamιdani M. Rehabilitation of orbital cavity after total orbital exenteration using oculofacial prostheses anchored byosseointegrated dental implants posed as a one step surgical procedure. Klin Monatsbl Augenheilkd 2006;223:400-4.  Back to cited text no. 1
    
2.
Lemon CJ, Kiat-amnuay S, Gettleman L, Martin JW, Chambers MS. Facial prosthetic rehabilitation: preprosthetic surgical technique and biomaterials. Curr Opin Otolaryngol Head Neck Surg 2005;13:255-62.  Back to cited text no. 2
    
3.
Wolfaardt J, Gehl G, Farmand M, Wilkes G. Indications and methods of care for aspects of extraoral osseointegration. Int J Oral Maxillofac Surg 2003;32:124-31.  Back to cited text no. 3
[PUBMED]  [FULLTEXT]  
4.
Beumer J, Ma T, Marunick M. Restoration of facial defects: Etiology, disability and rehabilitation. In: Beumer J, Curtis A, Marunick MT, editors. Maxillofacial rehabilitation: Prosthodontic and Surgical considerations. St. Louis: Ishiyaku Euro America; 1996. p. 377-453.  Back to cited text no. 4
    
5.
Heller HL, Mckinstry RE. Facial materials. In: McKinstry RE, editor. Fundamentals of facial prosthetics. Arlington: ABL Professional Publications; 1995. p. 79-97.  Back to cited text no. 5
    
6.
Chalian VA, Drane JB, Standish SM. Maxillofacial prosthetics, Multidisciplinary Practice. Baltimore: The Williams and Wilkins Co.; 1971; p. 129-37.  Back to cited text no. 6
    
7.
Metz HH. Maxillofacial prosthetic rehabilitation after mouth and facial surgery. J Prosthet Dent 1964;14:169-73.  Back to cited text no. 7
    
8.
Javid N. The use of magnets in a maxillofacial prosthesis. J Prosthet Dent 1971;25:234-7.  Back to cited text no. 8
    
9.
Otoofy L. An artificial nose for a chinaman. Dent Cosmos 1905;43:558.  Back to cited text no. 9
    
10.
Fonseca EP. The importance of form characterization and retention in facial prosthesis. J Prosthet Dent 1966;16:338-4.  Back to cited text no. 10
[PUBMED]    
11.
Rodrigues S, Shenoy VK, Shenoy K. Prosthetic rehabilitation of a patient after partial rhinectomy: A clinical report. J Prosthet Dent 2005;93:125-8.  Back to cited text no. 11
[PUBMED]  [FULLTEXT]  
12.
McArthur DR. Aids for positioning prosthetic eyes in orbital prosthesis. J Prosthet Dent 1977;37:320-6.  Back to cited text no. 12
[PUBMED]    
13.
Kiat-amnuay S, Lemon JC, Wesley PJ. Technique for fabricating a lightweight, urethane lined silicone orbital prosthesis. J Prosthet Dent 2001;86:210-3.  Back to cited text no. 13
    
14.
Khan Z, Bowden M, Beam D. Modified bar superstructure for an implant-retained orbital prosthesis. J Prosthodont 1994;3:65-7.  Back to cited text no. 14
[PUBMED]    
15.
Lerner TH, Huryn JM. Orbital prosthesis with a magnetically retained ocular component supported by osseointegrated implants. J Prosthet Dent 1993;69:378-80.  Back to cited text no. 15
[PUBMED]  [FULLTEXT]  
16.
Parel SM. Diminishing dependence on adhesives for retention of facial prosthesis. J Prosthet Dent 1980;43:552-60.  Back to cited text no. 16
[PUBMED]    
17.
Janeja OP, Madan KS, Mehra DM, Dogra NR. Orbital prosthesis. J Prosthet Dent 1976;36:307-10.  Back to cited text no. 17
    
18.
Cos WC. Ocular and acrylic orbital prosthesis presented at the third Annual symposium on maxillofacial prosthetics therapy. San Antonio, Texas: 1978.  Back to cited text no. 18
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10]


This article has been cited by
1 Prosthetic Rehabilitation of an Orbital Defect: A Case Report
Y. A. Bindhoo, U. Aruna
The Journal of Indian Prosthodontic Society. 2011;
[VIEW] | [DOI]
2 A Novel Method for Retention of an Orbital Prosthesis in a Case with Continuous Maxillary and Orbital Defect
Gunjan Pruthi, Veena Jain, Swati Sikka
The Journal of Indian Prosthodontic Society. 2010; 10(2): 132
[VIEW] | [DOI]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Case Reports
Discussion
Summary
Acknowledgments
References
Article Figures

 Article Access Statistics
    Viewed2225    
    Printed52    
    Emailed1    
    PDF Downloaded353    
    Comments [Add]    
    Cited by others 2    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]