• Users Online: 1069
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 


 
 Table of Contents  
CLINICAL REPORT
Year : 2009  |  Volume : 9  |  Issue : 3  |  Page : 171-174

Simplified technique for fabrication of custom ocular tray and making ocular impression


Department of Prosthodontics, K.L.E.S's Institute of Dental Sciences, Belgaum, Karnataka, India

Date of Web Publication14-Oct-2009

Correspondence Address:
K Preethi
KLE Vishwanath Katti Institute of Dental Sciences, Belgaum
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.57090

Rights and Permissions
  Abstract 

Prosthetic rehabilitation of an ocular defect can be successfully achieved with stock eye by using well fitting ocular tray and a proper impression technique. The tissue adaptation of stock prostheses can be improved by making an accurate impression of an ophthalmic socket using custom ocular tray. This article presents a technique for the fabrication of custom ocular tray and procedure for making impression of eye socket using the same.

Keywords: Ocular tray, ocular prosthesis, stock eye prosthesis


How to cite this article:
Hallikerimath R B, Preethi K, Dhaded S. Simplified technique for fabrication of custom ocular tray and making ocular impression. J Indian Prosthodont Soc 2009;9:171-4

How to cite this URL:
Hallikerimath R B, Preethi K, Dhaded S. Simplified technique for fabrication of custom ocular tray and making ocular impression. J Indian Prosthodont Soc [serial online] 2009 [cited 2020 May 30];9:171-4. Available from: http://www.j-ips.org/text.asp?2009/9/3/171/57090


  Introduction Top


Ocular prosthesis is an artificial replacement of bulb of the eye. A well-fitting ocular prosthesis enhances esthetics, improves facial contours and helps the patient overcome psychological trauma. Ocular prostheses are either ready made (stock) or custom made. [1] Stock prostheses are usually advocated when time is limited and cost is a consideration. [1] No special skills or material are required for its fabrication. [2] The use of stock ocular prosthesis of appropriate contour, size and color can provide an acceptable aesthetic result.

The tissue adaptation of stock prostheses can be improved by making an accurate impression of anophthalmic socket using custom ocular tray. Miller suggested that a custom ocular tray is necessary in certain situations like highly irregular anophthalmic socket or when there is non availability of stock trays. [2]


  Case Report Top


A male patient aged 45 years reported to the department of Prosthodontics, KLE Vishwanath Katti Institute of Dental Sciences, Belgaum, with a chief complaint of missing right eye. He gave a history of traumatic injury to the right eye in his childhood. On examination, intraocular tissue bed was healthy and with adequate depth between the upper and lower fornices for retention of the prosthesis.

[Figure 1] - Shows the technique used to fabricate custom ocular tray.


  Technique Top


A prefabricated stock eye that optimally fits the socket was selected. It was disinfected, lubricated and tissue side of the stock eye was invested with dental plaster (type 2, Goldstone, Asian chemicals, Gujarat, India) to the height of contour [Figure 2].

After the plaster was set, notches were made on the edges.

A small amount of polyvinyl siloxane putty (Aquasil, soft putty, Dentsply, Germany) was mixed and adapted over the top of invested prosthesis and into the notched edges.

After the putty was set, it was removed and a beveled sprue hole was made in the center of PVS cope.

The prosthesis was removed from the mold, plaster surface was lubricated and putty cope was replaced on the mold.

Self cure clear acrylic (DPI RR cold cure; Bombay Burma Trading Corp. Ltd.) was mixed and poured into mold space [Figure 3].

Once it was cured, the acrylic resin tray was removed from the mold and multiple perforations of three to four mm diameter were made in a tray and it was trimmed and polished.

The tube to inject impression material was fabricated by cutting the tip of syringe by about 10mm and it was secured to the ocular tray with cold cure acrylic resin [Figure 4].

The custom tray was disinfected and it was tried in patient for over extension and proper orientation [Figure 5].


  Impression Procedure Top


The impression tray was placed in the socket and the syringe was loaded with low viscosity poly-vinyl siloxane (Reprosil, Type 1, Dentsply, Germany)

The impression material was injected into the tray and patient was instructed to perform all the movements of the eye [Figure 6],[Figure 7].

After removal from the eye socket, the impression was invested first with dental stone (type 3, Goldstone, Asian chemicals, Gujarat, India) till the height of contour and then with dental plaster to get two-piece mold [Figure 8].

Stock eye was selected that matched the sclera and iris-pupil complex of the contra-lateral natural eye and it was trimmed precisely until it accurately fits into the socket [Figure 8].

The bulge of the eye was gained as of the contra-lateral eye by the addition of wax onto the tissue surface [Figure 9].

Once the correct bulge was obtained, the tissue surface of the prosthesis was again relined with soft tissue conditioner (Coe-soft, GC America INC) and placed into the socket to record the functional movements of the eye. [3]

The relined tissue side of the ocular prosthesis was invested, dewaxed and packed with heat cure clear acrylic resin (DPI RR Heat cure; Bombay Burma Trading Corp. Ltd.). [Figure 10]

The entire assembly was cured in 70 0 c water bath for one-and-a-half hours followed by 100 0 c water bath for 20 to 30 minutes. [4]

After the flask was cooled, prosthesis was separated from the investment and it was polished. The polished prosthesis must be free of roughness that could irritate the eye socket and encourage secretions to accumulate for additional irritation.

Prior to insertion of the polished prosthesis, it was disinfected in a solution of 0.5% chlorhexidine and 70% isopropyl alcohol for five minutes. After disinfection, the prosthesis was rinsed in sterile saline solution to avoid chemical irritation.


  Discussion Top


The custom ocular tray is based on the patient's existing anatomy, and therefore conforms accurately to the socket and helps in obtaining accurate impression of the eye socket. [2] This results in intimate adaptation of the stock eye prostheses to internal tissue surface of the socket.

Beumer et al. state that a prefabricated resin eye should not be used in eviscerated sockets because intimate contact between the ocular prosthesis and tissue bed is needed to distribute pressure equally. This is true if a prefabricated is selected and ground to close fit. However when prosthesis is customized to the patient using proper impression technique, distribution of pressure will be equal to. [4] In addition, intimate adaptation of the modified prosthesis to the tissue surface of the defect increases the movement of the prosthesis and enhances its natural appearance. [4]th


  Conclusion Top


A technique for the fabrication of custom ocular tray and impression procedure using the same has been described. This technique permits the finished ocular prosthesis to generate an equal distribution of pressure throughout the defect and intimate adaptation of the prosthesis to tissue surface of the defect.

A well-made, properly planned and functionally molded stock eye prosthesis maintains its orientation when patient performs various eye movements. It gives great psychological benefit and restores the cosmetic appearance of the patient.[Figure 11]

 
  References Top

1.
Cain JR. Custom ocular prosthetics. J Prosthet Dent 1982;48:690.  Back to cited text no. 1
[PUBMED]    
2.
Mathews MF, Smith RM, Sutton AJ, Hudson R. The Ocular Impression: A Review of the Literature and Presentation of an Alternate Technique. J Prosthodont 2000;9:210-6.  Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.
Ow RK, Amrith S. Ocular prosthetics: Use of a tissue conditioner material to modify a stock ocular prosthesis. J Prosthet Dent 1997;78:218-22.  Back to cited text no. 3
[PUBMED]  [FULLTEXT]  
4.
Taicher S, Steinberg HM, Tubiana I, Sela M. Modified Stock-eye Prosthesis. J Prosthet Dent 1985;54:95.  Back to cited text no. 4
[PUBMED]    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Case Report
Technique
Impression Procedure
Discussion
Conclusion
References
Article Figures

 Article Access Statistics
    Viewed957    
    Printed30    
    Emailed2    
    PDF Downloaded201    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]