• Users Online: 1110
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 18  |  Issue : 1  |  Page : 10-18

A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study


1 Department of Prosthodontics and Crown and Bridge, Sri Aurobindo College of Dentistry, Indore, Madhya Pradesh, India
2 Department of Oral and Maxillofacial Surgery, Government College of Dentistry, Indore, Madhya Pradesh, India

Correspondence Address:
Dr. Namrata Agrawal
Dr Garg's Advanced Dental Treatment Centre, 64/A, Patel Nagar, Opp. Vikram Tower, Indore - 452 001, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jips.jips_159_17

Rights and Permissions

Introduction: The two implant-supported overdentures have overcome the retention and stability-related problems of conventional mandibular denture. Stud attachments are widely available, less expensive, and easy to use. Aims and Objectives: To determine fatigue resistance of two different stud attachments with two denture base materials – autopolymerizing and heat cure acrylic resin till 4320 cycles simulating 03 years of service. Materials and Methods: Stud implant overdenture attachments, i.e., ball and socket and Dalla Bona attachments were tightened over the implants in two different mandibular edentulous base models. The housings were incorporated with both direct (chairside) and indirect (laboratory) technique into conventional mandibular dentures. These overdentures were subjected to continuous removal and insertion on Universal Testing Machine till 4320 cycles simulating 3 years of service assuming that patient takes out denture, 4 times in a day. The fatigue resistance was calculated for 0, 1440 (1 year), 2800 (2 years), and 4320 (3 years) cycles. Unpaired and paired t-tests were applied to find the level of significance. Results: Ball and socket attachments housed with heat cure acrylic resin (indirect technique) had the highest values of fatigue resistance at all cycles. Following were Dalla Bona attachments with autopolymerizing acrylic resin (direct technique), ball and socket attachments with autopolymerizing acrylic resin (direct technique), and Dalla Bona attachments with heat cure acrylic resin (indirect technique) as per statistical analysis. Conclusion: Two implant-supported mandibular overdenture with ball and socket attachments incorporated by indirect technique showed higher values in terms of retention and absence of disengagement/fracture of components.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1363    
    Printed34    
    Emailed0    
    PDF Downloaded251    
    Comments [Add]    

Recommend this journal