ORIGINAL STUDY NON-COMPETITION
Year : 2018  |  Volume : 18  |  Issue : 5  |  Page : 31-32

OSNC7: Influence of abutment material on stress distribution around maxillary anterior implants


Date of Web Publication31-Oct-2018

Correspondence Address:
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.244647

Rights and Permissions

How to cite this article:
... OSNC7: Influence of abutment material on stress distribution around maxillary anterior implants. J Indian Prosthodont Soc 2018;18, Suppl S1:31-2

How to cite this URL:
... OSNC7: Influence of abutment material on stress distribution around maxillary anterior implants. J Indian Prosthodont Soc [serial online] 2018 [cited 2018 Nov 20];18, Suppl S1:31-2. Available from: http://www.j-ips.org/text.asp?2018/18/5/31/244647



Parthasarathy Natarajan1, Angel Mary Elias2

1Reader, Sri Ramachandra Medical College and Research Institute, Porur, Chennai, India

2Royal Dental College, Kerala, India.

Aim: The purpose of this study was to investigate the combined influence of alveolar bone density, abutment material and occlusal forces on stress distribution around maxillary anterior implants in order to reduce the marginal bone loss and facial marginal recession for an optimal esthetic outcome.

Materials and Methods: A 3D Finite Element Model of a maxillary anterior single implant was generated from the CT image of the patient. Nine comparative groups were formed in D2 and D3 bone respectively. Three different abutment materials titanium, zirconia and PEEK (Poly-Ether-Ether Ketone) were used. External loads of 100N, 175N and 250N were applied in the vertical and oblique direction and the stress values were obtained from the labial aspect of the crestal bone.

Results: The highest Von Mises stress values were seen in the D3 bone when compared to the D2 bone. On vertical and oblique load of 100N, 175N and 250 N there was generalized higher stress values when PEEK was used as an abutment material. In all the groups, the stress values were greater on application of oblique load compared to vertical load and the stress increased for every increase of 75N.

Conclusion: The result of our study suggests that titanium and zirconia distribute the stresses in a more homogenous manner compared to the PEEK abutment.






 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article

 Article Access Statistics
    Viewed29    
    Printed0    
    Emailed0    
    PDF Downloaded19    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]