Year : 2018  |  Volume : 18  |  Issue : 5  |  Page : 45

CRNC1: Magnet repositioning on two separate custom tray for flabby ridge impression


Date of Web Publication31-Oct-2018

Correspondence Address:
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.244678

Rights and Permissions

How to cite this article:
. CRNC1: Magnet repositioning on two separate custom tray for flabby ridge impression. J Indian Prosthodont Soc 2018;18, Suppl S1:45

How to cite this URL:
. CRNC1: Magnet repositioning on two separate custom tray for flabby ridge impression. J Indian Prosthodont Soc [serial online] 2018 [cited 2018 Nov 20];18, Suppl S1:45. Available from: http://www.j-ips.org/text.asp?2018/18/5/45/244678



Ivana, Ismet Danial Nasution

Department of Prosthodontic, Faculty of Dentistry, Universitas Sumatera Utara, Medan 20155, Indonesia

Introduction: Accurate impression in complete edentulous patient with flabby ridge plays important role in the fabrication of well-fitting conventional complete denture. One of the impression technique to minimize tissue distortion of flabby ridge is window technique which also poses challenge for clinician. This case report presents reposition of two separate tray (window tray and pick up tray) by using magnet for flabby ridge impression.

Case Description: 63 year old male patient with chief complaint of ill-fitting complete denture visited Department of Prosthodontic. During intra oral examination, displaceable flabby tissue was found on anterior maxilla. Impression was taken by using two seperate tray. The first tray is window tray for recording posterior maxillary ridge with regular body polyvinylsiloxane (PVS) material. Afterwards, the anterior flabby ridge was recorded with the application of light body PVS through the window of the first tray, then the second pick up tray was placed with the help of magnet that was embedded on the tray.

Discussion: Window impression technique was modified by using a pick up tray with escape holes to control the application of light body PVS to obtain uniform thickness of the material without tissue distortion. In this case, we also embedded five pairs of magnet in the tray for accurate repositioning of the second tray to the first.

Conclusion: Proper diagnosis and treatment planning determine the success of the treatment. Therefore, accurate impression of the flabby ridge must be achieved without any displacement to provide better retention and stabilitation of conventional complete denture.






 

Top
 
 