CLINICAL REPORT |
|
Year : 2018 | Volume
: 18
| Issue : 6 | Page : 106 |
|
36. Simplified technique for orbital prosthesis fabrication: a clinical report
Tushar Krishnarao Mowade
VSPM Dental College, Nagpur
Date of Web Publication | 30-Nov-2018 |
Correspondence Address:
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/0972-4052.246611
How to cite this article: Mowade TK. 36. Simplified technique for orbital prosthesis fabrication: a clinical report. J Indian Prosthodont Soc 2018;18, Suppl S2:106 |
How to cite this URL: Mowade TK. 36. Simplified technique for orbital prosthesis fabrication: a clinical report. J Indian Prosthodont Soc [serial online] 2018 [cited 2019 Feb 18];18, Suppl S2:106. Available from: http://www.j-ips.org/text.asp?2018/18/6/106/246611 |
Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and achieving the retention and camouflaging the borders of orbital prosthesis. This presentation focuses on simple method of fabrication of silicon orbital prosthesis.
|