A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study


Prosthodontist

Date of Web Publication8-Jan-2021

Correspondence Address:
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.306338

Rights and Permissions

How to cite this article:
Garg NA. A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study. J Indian Prosthodont Soc 2020;20, Suppl S1:14-5

How to cite this URL:
Garg NA. A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study. J Indian Prosthodont Soc [serial online] 2020 [cited 2021 Jan 26];20, Suppl S1:14-5. Available from: https://www.j-ips.org/text.asp?2020/20/5/14/306338



Introduction: The two implant-supported overdentures have overcome the retention and stability-related problems of conventional mandibular denture. According to McGill Consensus statement, it is minimally acceptable solution for patients that cannot go extensive implant and prosthetic treatment though not the best option. Stud attachments are widely available, less expensive, and easy to use. Our study aimed to determine fatigue resistance of two different stud attachments with two denture base materials - autopolymerizing and heat cure acrylic resin till 4320 cycles simulating 03 years of service.

Methodology: Stud implant overdenture attachments, i.e., ball & socket and Dalla Bona attachments were tightened over the implants in two different mandibular edentulous base models. The housings were incorporated with both direct (chairside) and indirect (laboratory) technique into conventional mandibular dentures. These overdentures were subjected to continuous removal and insertion on Universal Testing Machine till 4320 cycles simulating 3 years of service assuming that patient takes out denture, 4 times in a day. The fatigue resistance was calculated for 0, 1440 (1 year), 2800 (2 years), and 4320 (3 years) cycles. Unpaired and paired t-tests were applied to find the level of significance.

Result: Ball & socket attachments housed with heat cure acrylic resin (indirect technique) had the highest values of fatigue resistance at all cycles. Following were Dalla Bona attachments with autopolymerizing acrylic resin (direct technique), ball & socket attachments with autopolymerizing acrylic resin (direct technique), and Dalla Bona attachments with heat cure acrylic resin (indirect technique) as per statistical analysis.

Conclusion: Two implant-supported mandibular overdenture with ball & socket attachments incorporated by indirect technique showed higher values in terms of retention and absence of disengagement/fracture of component.






 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article

 Article Access Statistics
    Viewed38    
    Printed0    
    Emailed0    
    PDF Downloaded2    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]